MnCL2/γ-AL2O3改性氧化鋁填充柱 氘氣中氫同位素的低溫氣相色譜法測定
產品名稱:MnCL2/γ-AL2O3改性氧化鋁填充柱 氘氣中氫同位素的低溫氣相色譜法測定
產品型號:MnCL2/γ-AL2O3改性氧化鋁填充柱
產品廠商:浩瀚色譜(山東)應用技術開發有限公司
簡單介紹
氘氣中氫同位素的低溫氣相色譜法測定,液化石油氣,二甲醚,甲縮醛,乙縮醛,乙醇,室內空氣,焦爐煤氣,煉廠氣,天然氣,變壓器油,多氯聯苯,植物油,增塑劑,塑化劑,醫療器械
MnCL2/γ-AL2O3改性氧化鋁填充柱 氘氣中氫同位素的低溫氣相色譜法測定的詳細介紹
氘氣中氫同位素的低溫氣相色譜法測定
氘氣中氫同位素的低溫氣相色譜法測定 詳細信息:
浩瀚色譜(山東)應用技術開發有限公司針對高純氘氣中H2、HD與D2等氫同位素氣體間不易分離分析的特點,以改性的氧化鋁色譜柱,在-95℃下對氫同位素進行分離,以氣相色譜-脈沖放電氦離子化檢測器對氫同位素進行分析。研究建立的H2、HD與D2等同位素氣體測定方法精密度小于15%,小檢出摩爾分數為1×10-6。
氘氣中氫同位素的低溫氣相色譜法測定 測試譜圖:
Determination of Hydrogen Isotope in Deuterium Gas by Low Temperature Gas Chromatography
Determination of Hydrogen Isotope in Deuterium Gas by Low Temperature Gas Chromatography Details:
Name: Modified alumina packed column
Specification: 4m*3mm
Model: MnCL2/γ-AL2O3, 60-80 mesh
Application: hydrogen isotope determination
Haohan Chromatography (Shandong) Applied Technology Development Co., Ltd. aims at the difficult separation and analysis of hydrogen isotope gases such as H2, HD and D2 in high-purity deuterium gas, and uses a modified alumina chromatographic column to perform hydrogen isotope analysis at -95°C. After separation, the hydrogen isotope was analyzed by gas chromatography-pulsed discharge helium io nization detector. The research established H2, HD and D2 isotopic gas determination method has a precision of less than 15%, and the minimum detected mole fraction is 1×10-6.
Determination of hydrogen isotopes in deuterium gas by low-temperature gas chromatography Test spectrum:
氘氣中氫同位素的低溫氣相色譜法測定 詳細信息:
名稱:改性氧化鋁填充柱
規格:4m*3mm
型號:MnCL2/γ-AL2O3,60-80目
應用:氫同位素測定
浩瀚色譜(山東)應用技術開發有限公司針對高純氘氣中H2、HD與D2等氫同位素氣體間不易分離分析的特點,以改性的氧化鋁色譜柱,在-95℃下對氫同位素進行分離,以氣相色譜-脈沖放電氦離子化檢測器對氫同位素進行分析。研究建立的H2、HD與D2等同位素氣體測定方法精密度小于15%,小檢出摩爾分數為1×10-6。
氘氣中氫同位素的低溫氣相色譜法測定 測試譜圖:
Determination of Hydrogen Isotope in Deuterium Gas by Low Temperature Gas Chromatography
Determination of Hydrogen Isotope in Deuterium Gas by Low Temperature Gas Chromatography Details:
Name: Modified alumina packed column
Specification: 4m*3mm
Model: MnCL2/γ-AL2O3, 60-80 mesh
Application: hydrogen isotope determination
Haohan Chromatography (Shandong) Applied Technology Development Co., Ltd. aims at the difficult separation and analysis of hydrogen isotope gases such as H2, HD and D2 in high-purity deuterium gas, and uses a modified alumina chromatographic column to perform hydrogen isotope analysis at -95°C. After separation, the hydrogen isotope was analyzed by gas chromatography-pulsed discharge helium io
Determination of hydrogen isotopes in deuterium gas by low-temperature gas chromatography Test spectrum: